Brightened strobe control for short, high-intensity exposure
LXV-4STU raises light output two to ten times for a controlled pulse. It provides a 12 μs fixed trigger delay, adjustable lighting, delay and filter timing, internal self-triggering, RS232/LAN communication and a 12 V camera synchronization output.
- Trigger response
- 12 μs
- Fixed lighting delay
- Pulse width
- 0–999 μs
- N series
- Brightening
- 2–10×
- Instantaneous output mode
- Communication
- RS232 / LAN
- 19200 bps default
Freeze fast motion
Use a short bright pulse to reduce motion blur.
Self-triggered stations
Set an internal frequency where no external trigger generator is available.
Camera synchronization
Use the 12 V pulse output to trigger the camera with the light.
Remote adjustment
Set timing and brightness from a PC or the panel encoder.
Adjustable strobe timing from trigger input to synchronized camera exposure
After a trigger, the light begins after the fixed 12 μs delay. Lighting duration, output trigger timing, camera delay and filter time are configurable within the selected N or P series limits.
- Working modes
- Internal self-triggering or external trigger mode.
- N series
- 0–999 μs lighting time and 1–200 Hz internal triggering.
- P series
- 0–100 μs lighting time and 1–50 Hz internal triggering.
- Sequence timing
- The sequence chart defines trigger-to-light delay T1 ≤12 μs, camera delay T3 ≤30 μs and lighting time T5 ≤999 μs.
- Trigger handling
- 5–24 V rising or falling edge can be selected; adjustable delay 0–999 μs and filter 0–999 μs / 1–999 ms.
Match timing, voltage, load and channel count
Select the exact controller row from the connected lights, trigger plan and communication requirement.
- 1
Set exposure duration
Choose the pulse needed to freeze the target.
- 2
Choose N or P series
Use N for up to 999 μs/200 Hz or P for up to 100 μs/50 Hz.
- 3
Choose channels
Match two or four independently connected lights.
- 4
Validate brightened load
Confirm the exact light and controller combination at full duty.
Read the controller model pattern
LXV-4STU 48 [power]-[channels][N/P]- LXV
- Product prefix
- 4STU
- Brightened strobe controller
- 48
- 48 V output
- Power
- 60 / 120 / 200 class
- Channels
- 2 or 4
- N / P
- Pulse-series timing range
LXV-4STU model range
Each voltage, timing, channel and dimension value remains attached to its own model.
| Model | Output | Channels | Lighting time | Trigger frequency | Dimension | External trigger |
|---|---|---|---|---|---|---|
| LXV-4STU4860-2N | 48 V | 2 | 0–999 μs | ≤200 Hz | 1 | 5–24 V |
| LXV-4STU4860-4N | 48 V | 4 | 0–999 μs | ≤200 Hz | 1 | 5–24 V |
| LXV-4STU48120-2N | 48 V | 2 | 0–999 μs | ≤200 Hz | 1 | 5–24 V |
| LXV-4STU48120-4N | 48 V | 4 | 0–999 μs | ≤200 Hz | 1 | 5–24 V |
| LXV-4STU48200-2N | 48 V | 2 | 0–999 μs | ≤200 Hz | 2 | 5–24 V |
| LXV-4STU48200-4N | 48 V | 4 | 0–999 μs | ≤200 Hz | 3 | 5–24 V |
| LXV-4STU48120-4P | 48 V | 4 | 0–100 μs | ≤50 Hz | 1 | 5–24 V |
| LXV-4STU48200-2P | 48 V | 2 | 0–100 μs | ≤50 Hz | 2 | 5–24 V |
| LXV-4STU48200-4P | 48 V | 4 | 0–100 μs | ≤50 Hz | 3 | 5–24 V |
Wire signal, load and communication before releasing the controller
Use the exact model row and mechanical drawing; validate the complete light, camera and trigger sequence together.
- 01
Connect PC communication through RS232 or LAN if recipes are remote.
- 02
Connect PLC/sensor to the 5–24 V trigger input with the selected edge polarity.
- 03
Connect camera synchronization output and verify its 12 V pulse compatibility.
- 04
Use dimension group 1, 2 or 3 from the selected model row.
Confirm electrical and timing compatibility
- Light voltage, total load and channel load
- Trigger voltage, edge, pulse width and frequency
- Camera trigger level and timing
- Communication, mounting and ventilation