Constant-current control for high-power line-scan illumination
LXV-3DPA is the constant-current controller family identified for line-scan lights. It combines encoder or PC adjustment, high-level external triggering, communication and protection alarms across 60–1350 W models.
- Drive mode
- Constant current
- Stable, flicker-free output
- Adjustment
- 256 levels
- Encoder or PC
- Trigger
- 5–24 V
- High-level valid
- Frequency
- Up to 7.5 kHz
- At 50% duty ratio
- Communication
- RS232 / LAN
- Model-family function
Line-scan lighting
Use constant-current drive where stable light output and repeatable digital adjustment are required for line-scan acquisition.
Remote recipes
Use RS232 or Ethernet communication to set one of 256 luminance levels from the host system.
Triggered capture
Use the 5–24 V input with the stated timing limits when illumination must follow a PLC or sensor signal.
Protected high-power loads
Alarms cover LED open circuit, short circuit and overload, together with power-off setting retention.
Choose voltage, power, channel count and enclosure from one model row
The family includes 24 V and 48 V controllers. Keep each light within the one-channel limit and all active lights within the total-power limit of the same model.
Host control, trigger behavior and electrical interface
The working system shows PC communication through RS232 or LAN, a PLC/sensor trigger input and a dedicated controller-to-light cable.
| Parameter | Operating value |
|---|---|
| Input supply | AC 100–240 V |
| Adjustment resolution | 256 levels |
| Adjustment methods | Manual encoder knob or PC remote adjustment |
| Drive mode | Constant current |
| Baud rate | 9600 bps |
| External trigger | High level 5–24 V valid |
| Maximum stated trigger frequency | 7.5 kHz at 50% external-trigger duty ratio |
| External trigger delay | 10 μs |
| Communication | RS232 / LAN |
| Constant on/off | TS switch |
| Memory | Automatic data saving at power off |
| Operating environment | 0–50 °C; 20–85% RH, non-condensing |
| Storage environment | 0–60 °C; 20–85% RH, non-condensing |
5–24 V high-level input with NPN and PNP references
In MANU mode, applying the high-level signal turns the light off; in REMO mode it turns the light on. T1 is turn-on delay, T2 is the lighting interval and T3 is turn-off delay. T1 ≤ 10 μs and T3 ≤ 10 μs.
Compare all 14 constant-current controller configurations
Model codes combine output voltage, total-power family and channel count. The S/M suffixes and dimension group distinguish enclosure variants.
- 1
Match light voltage
Separate the 24 V and 48 V controller families first.
- 2
Check each channel
Keep every connected light below the stated one-channel maximum.
- 3
Check total load
Add all active lights and keep the result within total output.
- 4
Release the exact housing
Use the same row’s dimension number for mechanical integration.
LXV-3DPA [voltage] [total power]-[channels / housing]- LXV
- LuxMV product prefix
- 3DPA
- High-power constant-current controller
- 24 / 48
- Output-voltage family
- 60–1500
- Power-family code
- 1 / 2 / 4 + S/M
- Channels and enclosure suffix
| Model | Maximum total output | One-channel maximum | Channels | Dimension group | Trigger |
|---|---|---|---|---|---|
| LXV-3DPA2460-2S | 60 W | 40 W | 2 | 1 | 5–24 V |
| LXV-3DPA2460-4S | 60 W | 40 W | 4 | 1 | 5–24 V |
| LXV-3DPA24120-1M | 120 W | 120 W | 1 | 2 | 5–24 V |
| LXV-3DPA24120-2M | 120 W | 120 W | 2 | 2 | 5–24 V |
| LXV-3DPA24200-1M | 200 W | 200 W | 1 | 2 | 5–24 V |
| LXV-3DPA24200-2M | 200 W | 120 W | 2 | 2 | 5–24 V |
| LXV-3DPA24320-1S | 320 W | 320 W | 1 | 3 | 5–24 V |
| LXV-3DPA24320-2S | 320 W | 240 W | 2 | 3 | 5–24 V |
| LXV-3DPA24500-1S | 450 W | 450 W | 1 | 4 | 5–24 V |
| LXV-3DPA24500-2S | 450 W | 240 W | 2 | 4 | 5–24 V |
| LXV-3DPA24500-4S | 450 W | 120 W | 4 | 5 | 5–24 V |
| LXV-3DPA48750-1S | 700 W | 700 W | 1 | 6 | 5–24 V |
| LXV-3DPA481000-1S | 900 W | 900 W | 1 | 7 | 5–24 V |
| LXV-3DPA481500-1S | 1350 W | 1350 W | 1 | 8 | 5–24 V |
Plan enclosure size, mounting, connector access and cooling
Eight mechanical groups span compact DIN-rail controllers, ventilated multi-channel housings and handled high-power enclosures.
| Group | Models | Overall width | Overall height | Overall depth | Mounting |
|---|---|---|---|---|---|
| 1 | 2460-2S / 4S | 100 mm | 156 mm | 134 mm | DIN guide-rail base |
| 2 | 24120 / 24200-1M / 2M | 135 mm | 155.8 mm | 134 mm | DIN guide-rail base |
| 3 | 24320-1S / 2S | 182 mm | 126 mm | 262 mm | Removable base; 4 × M3 holes |
| 4 | 24500-1S / 2S | 182 mm | 126 mm | 262 mm | Removable base; 4 × M3 holes |
| 5 | 24500-4S | 192 mm | 126 mm | 292 mm | Removable base; 4 × M3 holes |
| 6 | 48750-1S | 192 mm | 126 mm | 292 mm | Removable base; 4 × M3 holes |
| 7 | 481000-1S | 160 mm | 148.6 mm | 430 mm | Handled housing |
| 8 | 481500-1S | 208 mm | 148.6 mm | 450 mm | Handled housing |
Use the dimension group from the selected model row
Do not infer one enclosure from power alone. Confirm the S/M suffix, mounting base and all overall dimensions against the corresponding drawing.
Keep the control, communication and cooling faces accessible
Allow working room for AC input, light outputs, trigger terminals, RS232/LAN, encoder controls, fans, ventilation and handled-enclosure access.