Choose the controller architecture from the light and timing requirement
The comparison separates constant-current, PWM digital, analog constant-voltage, alternate strobe, brightened strobe, dust-proof and synchronous-control families. It contains 91 documented configurations rather than one controller model.
- Configurations
- 91
- Complete model rows
- Channels
- 1–12
- Model dependent
- Communication
- Panel / RS232 / LAN
- Series dependent
- Trigger
- 0–1.5 / 5–24 V
- Where supported
Continuous intensity
Choose constant-current, analog or PWM according to the light electrical design.
High-speed strobe
Choose alternate or brightened strobe from the required pulse and synchronization.
Protected installation
Use dust-proof variants when the controller environment requires it.
System coordination
Use SHT where several controllers and cameras share one timing sequence.
What changes between controller architectures
Electrical mode determines how the light is driven; communication and triggering determine how it participates in the machine cycle.
- Constant voltage
- Adjusts luminance by voltage while holding the set voltage; suited to line-scan and high-speed shutter cameras.
- PWM digital
- Adjusts duty ratio, shortens lighting time and heat, and supports 256-level key, encoder, RS232 or model-dependent LAN control.
- Constant current
- Adjusts LED current with current self-detection for line-scan and high-speed shutter cameras.
- Brightened strobe
- Applies 48 V for an instant, supports 0–999 μs lighting and can raise instantaneous luminance while limiting on-time.
- Analog adjustment
- Uses an external rotary knob for stepless 0–100% luminance adjustment.
- Trigger versus brightened strobe
- Trigger strobe is shown at up to 24 V with light pulse width following the trigger input; brightened strobe is shown at up to 48 V with a limited 0–999 μs pulse.
- Synchronous logic
- Coordinates controller and camera triggers through countdown, I/O-port and signal-generator modes rather than powering the light directly.
Series-level selection matrix
| Mode | Series | Channels | Communication | Electrical range | Use when |
|---|---|---|---|---|---|
| Constant current | LXV-3ACC | 1–4 channels | RS232 / RS232+LAN | 0–2500 mA | Choose where LED current, rather than voltage, defines the load. |
| Constant current | LXV-3DPA | 1–4 channels | RS232 + LAN | 40–1350 W per channel | Covers small, medium and high-power constant-current loads. |
| PWM digital | LXV-3DPC | 2–12 channels | RS232 / RS232+LAN | 24 V, 40–60 W per channel | Use for multi-channel constant-voltage PWM control. |
| Analog constant voltage | LXV-3APC | 2–4 channels | Panel / external trigger | 24 V | Use for manual analog intensity control. |
| Compact analog | LXV-2APC / APC | 1–2 channels | Panel / trigger | 24 V | Use for compact low-channel installations. |
| Alternate strobe | LXV-3DRC | 2–4 channels | RS232 + LAN | 24 / 48 V | Use time-sharing or independent line-scan triggering. |
| Brightened strobe | LXV-4STU | 2–4 channels | RS232 + LAN | 48 V | Use short 2–10× brightened pulses with camera synchronization. |
| Dust-proof | LXV-IP | 1 or 8 channels | Model dependent | 24 V | Use sealed controller variants for dusty installations. |
| Synchronous logic | LXV-SHT | 6 outputs | RS232 + LAN | Logic outputs | Coordinate multiple controllers and cameras. |
Move from architecture to one exact controller row
The comparison narrows the family; retain the exact row for voltage or current, per-output limit, total load, channels, communication, trigger and supply.
- 1
Identify the light drive
Confirm constant current or constant voltage, output voltage, total load and maximum channel load.
- 2
Define control timing
Set continuous, PWM, alternating or brightened strobe operation.
- 3
Count channels and devices
Include every independently controlled light and camera trigger.
- 4
Choose communication and environment
Confirm panel, RS232, LAN, trigger voltage and protection needs.
91 documented controller configurations
Every electrical and timing value remains attached to its own model row.
| Mode | Series | Model | Channels | Communication | Output / current | Per-output / timing | Total output | Trigger | Input supply |
|---|---|---|---|---|---|---|---|---|---|
| Constant voltage | Alternate strobe | LXV-3DRC24250-2N | 2 | RS232 / LAN | 24 V | 250 W | 250 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | Alternate strobe | LXV-3DRC24250-4N | 4 | RS232 / LAN | 24 V | 250 W | 250 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | Alternate strobe | LXV-3DRC48400-2N | 2 | RS232 / LAN | 48 V | 400 W | 400 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | Alternate strobe | LXV-3DRC48400-4N | 4 | RS232 / LAN | 48 V | 400 W | 400 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | Alternate strobe | LXV-3DRC481000-2N | 2 | RS232 / LAN | 48 V | 1000 W | 2000 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | APC controller box | LXV-APC2424-2F | 2 | — | 24 V | 24 W | 48 W | Y · 0–1.5 V | DC 24 V |
| Constant voltage | APC controller box | LXV-3APC2460-2F | 2 | — | 24 V | 30 W | 60 W | Y · 0–1.5 V | DC 24 V |
| Constant voltage | 3APC small power | LXV-3APC2424-1 | 1 | — | 24 V | 24 W | 24 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 3APC small power | LXV-3APC2424-2 | 2 | — | 24 V | 24 W | 24 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 3APC small power | LXV-3APC2424-4 | 4 | — | 24 V | 24 W | 24 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 3APC small power | LXV-3APC2460-1 | 1 | — | 24 V | 60 W | 60 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 3APC small power | LXV-3APC2460-2 | 2 | — | 24 V | 30 W | 60 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 3APC small power | LXV-3APC2460-4 | 4 | — | 24 V | 24 W | 60 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 3APC medium power | LXV-3APC24120-1 | 1 | — | 24 V | 120 W | 120 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 3APC medium power | LXV-3APC24120-2 | 2 | — | 24 V | 90 W | 120 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 3APC medium power | LXV-3APC24120-4 | 4 | — | 24 V | 60 W | 120 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 3APC medium power | LXV-3APC24200-1 | 1 | — | 24 V | 180 W | 180 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 3APC medium power | LXV-3APC24200-2 | 2 | — | 24 V | 90 W | 180 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 3APC medium power | LXV-3APC24200-4 | 4 | — | 24 V | 60 W | 180 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 2APC small power | LXV-2APC2424-1 | 1 | — | 24 V | 24 W | 24 W | Y · 0–1.5 V | AC 100–240 V |
| Constant voltage | 2APC small power | LXV-2APC2424-2 | 2 | — | 24 V | 24 W | 24 W | Y · 0–1.5 V | AC 100–240 V |
| Constant voltage | 2APC small power | LXV-2APC2424-4 | 4 | — | 24 V | 24 W | 24 W | Y · 0–1.5 V | AC 100–240 V |
| Constant voltage | 2APC medium power | LXV-2APC2460-1 | 1 | — | 24 V | 60 W | 60 W | Y · 0–1.5 V | AC 100–240 V |
| Constant voltage | 2APC medium power | LXV-2APC2460-2 | 2 | — | 24 V | 30 W | 60 W | Y · 0–1.5 V | AC 100–240 V |
| Constant voltage | 2APC medium power | LXV-2APC2460-4 | 4 | — | 24 V | 24 W | 60 W | Y · 0–1.5 V | AC 100–240 V |
| Constant voltage | 2APC medium power | LXV-2APC2460-6 | 6 | — | 24 V | 24 W | 60 W | Y · 0–1.5 V | AC 100–240 V |
| Constant voltage | 2APC medium power | LXV-2APC24120-1 | 1 | — | 24 V | 120 W | 120 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 2APC medium power | LXV-2APC24120-2 | 2 | — | 24 V | 60 W | 120 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 2APC medium power | LXV-2APC24120-8 | 8 | — | 24 V | 24 W | 120 W | Y · 0–1.5 V | AC 100–240 V |
| Constant voltage | 2APC high power | LXV-2APC24200-1 | 1 | — | 24 V | 180 W | 180 W | Y · 5–24 V | AC 100–240 V |
| Constant voltage | 2APC high power | LXV-2APC24400-1 | 1 | — | 24 V | 360 W | 360 W | Y · 5–24 V | AC 200–240 V |
| Constant voltage | 2APC high power | LXV-2APC24400-2 | 2 | — | 24 V | 180 W | 360 W | Y · 5–24 V | AC 200–240 V |
| Constant voltage | 2APC high power | LXV-2APC481000-1 | 1 | — | 48 V | 1000 W | 1000 W | Y · 5–24 V | AC 90–264 V |
| Constant voltage | 2APC high power | LXV-2APC481500-1 | 1 | — | 48 V | 1500 W | 1500 W | Y · 5–24 V | AC 90–264 V |
| Brightened strobe | 4STU brightened strobe | LXV-4STU4860-2N | 2 | RS232 / LAN | 48 V | 0–999 μs | — | Y · 5–24 V | AC 100–240 V |
| Brightened strobe | 4STU brightened strobe | LXV-4STU4860-4N | 4 | RS232 / LAN | 48 V | 0–999 μs | — | Y · 5–24 V | AC 100–240 V |
| Brightened strobe | 4STU brightened strobe | LXV-4STU48120-2N | 2 | RS232 / LAN | 48 V | 0–999 μs | — | Y · 5–24 V | AC 100–240 V |
| Brightened strobe | 4STU brightened strobe | LXV-4STU48120-4N | 4 | RS232 / LAN | 48 V | 0–999 μs | — | Y · 5–24 V | AC 100–240 V |
| Brightened strobe | 4STU brightened strobe | LXV-4STU48200-2N | 2 | RS232 / LAN | 48 V | 0–999 μs | — | Y · 5–24 V | AC 100–240 V |
| Brightened strobe | 4STU brightened strobe | LXV-4STU48200-4N | 4 | RS232 / LAN | 48 V | 0–999 μs | — | Y · 5–24 V | AC 100–240 V |
| Brightened strobe | 4STU brightened strobe | LXV-4STU48120-4P | 4 | RS232 / LAN | 48 V | 0–100 μs | — | Y · 5–24 V | AC 100–240 V |
| Brightened strobe | 4STU brightened strobe | LXV-4STU48200-2P | 2 | RS232 / LAN | 48 V | 0–100 μs | — | Y · 5–24 V | AC 100–240 V |
| Brightened strobe | 4STU brightened strobe | LXV-4STU48200-4P | 4 | RS232 / LAN | 48 V | 0–100 μs | — | Y · 5–24 V | AC 100–240 V |
| Constant current | 3ACC constant current | LXV-3ACC350-2C | 2 | RS232 | 0–350 mA | 1 W | 2 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3ACC constant current | LXV-3ACC350-4C | 4 | RS232 | 0–350 mA | 1 W | 4 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3ACC constant current | LXV-3ACC700-2C | 2 | RS232 | 0–700 mA | 2 W | 4 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3ACC constant current | LXV-3ACC700-4C | 4 | RS232 | 0–700 mA | 2 W | 8 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3ACC constant current | LXV-3ACC1000-2C | 2 | RS232 | 0–1000 mA | 3 W | 6 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3ACC constant current | LXV-3ACC1000-4C | 4 | RS232 | 0–1000 mA | 3 W | 12 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3ACC constant current | LXV-3ACC1500-2C | 2 | RS232 | 0–1500 mA | 5 W | 10 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3ACC constant current | LXV-3ACC1500-4C | 4 | RS232 | 0–1500 mA | 5 W | 20 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3ACC constant current | LXV-3ACC2500-2C | 2 | RS232 | 0–2500 mA | 10 W | 20 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3ACC constant current | LXV-3ACC12400-2 | 2 | RS232 / LAN | 0–400 mA | 5 W | 10 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3ACC constant current | LXV-3ACC12700-1 | 1 | RS232 / LAN | 0–700 mA | 8.5 W | 8.5 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA small power | LXV-3DPA2460-2S | 2 | RS232 / LAN | — | 40 W | 60 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA small power | LXV-3DPA2460-4S | 4 | RS232 / LAN | — | 40 W | 60 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA medium power | LXV-3DPA24120-1M | 1 | RS232 / LAN | — | 120 W | 120 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA medium power | LXV-3DPA24120-2M | 2 | RS232 / LAN | — | 120 W | 120 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA medium power | LXV-3DPA24200-1M | 1 | RS232 / LAN | — | 200 W | 200 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA medium power | LXV-3DPA24200-2M | 2 | RS232 / LAN | — | 120 W | 200 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA high power | LXV-3DPA24320-1S | 1 | RS232 / LAN | — | 320 W | 320 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA high power | LXV-3DPA24320-2S | 2 | RS232 / LAN | — | 240 W | 320 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA high power | LXV-3DPA24500-1S | 1 | RS232 / LAN | — | 450 W | 450 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA high power | LXV-3DPA24500-2S | 2 | RS232 / LAN | — | 240 W | 450 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA high power | LXV-3DPA24500-4S | 4 | RS232 / LAN | — | 120 W | 450 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA high power | LXV-3DPA48750-1S | 1 | RS232 / LAN | — | 700 W | 700 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA high power | LXV-3DPA481000-1S | 1 | RS232 / LAN | — | 900 W | 900 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA high power | LXV-3DPA481500-1S | 1 | RS232 / LAN | — | 1350 W | 1350 W | Y · 5–24 V | AC 100–240 V |
| Constant current | 3DPA high power | LXV-3DPA24350-1SA | 1 | RS232 / LAN | — | 320 W | 320 W | Y · 5–24 V | AC 100–240 V · switch |
| Constant current | 3DPA high power | LXV-3DPA24350-2SA | 2 | RS232 / LAN | — | 240 W | 320 W | Y · 5–24 V | AC 100–240 V · switch |
| Constant current | 3DPA high power | LXV-3DPA481000-1SA | 1 | RS232 / LAN | — | 900 W | 900 W | Y · 5–24 V | 110 / 220 VAC · switch |
| Constant current | 3DPA high power | LXV-3DPA481500-1SA | 1 | RS232 / LAN | — | 1350 W | 1350 W | Y · 5–24 V | AC 180–264 V |
| PWM digital | 3DPC controller box | LXV-3DPC2480-4F | 4 | RS232 | 24 V | 80 W | 80 W | Y · 5–24 V | DC 24 V |
| PWM digital | 3DPC medium power | LXV-3DPC2460-2C | 2 | RS232 | 24 V | 40 W | 60 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC medium power | LXV-3DPC2460-4C | 4 | RS232 | 24 V | 40 W | 60 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC high power | LXV-3DPC24120-4C | 4 | RS232 | 24 V | 60 W | 120 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC high power | LXV-3DPC24120-8C | 8 | RS232 | 24 V | 60 W | 120 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC high power | LXV-3DPC24200-4C | 4 | RS232 | 24 V | 60 W | 200 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC high power | LXV-3DPC24200-8C | 8 | RS232 | 24 V | 60 W | 200 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC medium power | LXV-3DPC2460-2S | 2 | RS232 / LAN | 24 V | 40 W | 60 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC medium power | LXV-3DPC2460-4S | 4 | RS232 / LAN | 24 V | 40 W | 60 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC high power | LXV-3DPC24120-4S | 4 | RS232 / LAN | 24 V | 60 W | 120 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC high power | LXV-3DPC24120-8S | 8 | RS232 / LAN | 24 V | 60 W | 120 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC high power | LXV-3DPC24200-4S | 4 | RS232 / LAN | 24 V | 60 W | 200 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC high power | LXV-3DPC24200-8S | 8 | RS232 / LAN | 24 V | 60 W | 200 W | Y · 5–24 V | AC 100–240 V |
| PWM digital | 3DPC high power | LXV-3DPC24200-12S | 12 | RS232 / LAN | 24 V | 60 W | 200 W | Y · 5–24 V | AC 100–240 V |
| Synchronous logic | SHT synchronous control module | LXV-SHT2430-1 | 6 | RS232 / LAN | Logic output | 1–999 μs / 1–999 ms | 1–100 kHz · 0–100% duty | Y · 5–24 V | DC 24 V |
| IP dust-proof | IP dust-proof controller | LXV-3DPC24120-8S-IP | 8 | RS232 / LAN | 24 V | 60 W | 120 W | Y · 5–24 V | AC 100–240 V |
| IP dust-proof | IP dust-proof controller | LXV-3DPC24200-8S-IP | 8 | RS232 / LAN | 24 V | 60 W | 200 W | Y · 5–24 V | AC 100–240 V |
| IP dust-proof | IP dust-proof controller | LXV-APC24240-1-IP | 1 | — | 24 V | 240 W | 240 W | — | AC 100–240 V |
| IP dust-proof | IP dust-proof controller | LXV-APC24480-1-IP | 1 | — | 24 V | 480 W | 480 W | — | AC 100–240 V |
Use dimensions and wiring from the selected controller only
The comparison route has no universal enclosure. Mechanical drawings, terminal definitions and cable clearances belong to each controller family and model.
- 01
Open the selected controller family and retain one complete model row.
- 02
Verify light voltage, current/power and per-channel limits before connection.
- 03
Verify PLC/sensor trigger level, edge, pulse and camera synchronization.
- 04
Release the enclosure, DIN rail, ventilation and connector access from its drawing.
Provide the complete connected system
- Every light model and electrical load
- Required independent channels
- Trigger source, frequency and pulse timing
- Camera outputs, communication and enclosure