Stepless analogue control from compact stations to 1500 W lighting loads
LXV-2APC is a constant-voltage analogue-controller family with manual stepless adjustment, an output-voltage display, external triggering and a 12 V auxiliary output for camera power. Select voltage, load, channel count, trigger family and housing together.
- Output voltage
- 24 / 48 V
- Model-dependent
- Total output
- 24–1500 W
- Use the exact row
- Channels
- 1 / 2 / 4 / 6 / 8
- Model-dependent
- Trigger families
- 0–1.5 / 5–24 V
- Do not interchange
- Adjustment
- Stepless
- Manual knob
Compact manual control
Use the smaller 24 W and 60 W configurations for one to six independently adjusted light channels.
Multi-light stations
Use the eight-channel 120 W model where several low-power lights require separate front-panel adjustment.
High-power illumination
Use the 180 W, 360 W, 1000 W or 1500 W rows only with the matching 24 V or 48 V light load.
PLC or sensor timing
Choose the controller whose 0–1.5 V or 5–24 V trigger input matches the production signal.
Voltage and trigger family are fixed by the model row
A higher power rating does not make two controllers electrically interchangeable. Confirm output voltage, input supply, trigger level, total power and per-channel power before connection.
Working system, controller functions and two trigger architectures
The PLC or sensor drives the selected trigger input; the controller then powers the connected machine-vision light through its light cable.
| Function | Operating value |
|---|---|
| Output families | 24 V and 48 V |
| Channel options | 1, 2, 4, 6 or 8 |
| Input supply | AC 100–240 V, AC 200–240 V or AC 90–264 V by model |
| Input frequency | 50/60 Hz |
| Luminance adjustment | Manual adjusting knob |
| Adjustment level | Stepless |
| Drive mode | Constant voltage |
| Auxiliary output | 12 V output for camera power |
| Constant on/off | TS toggle switch |
0–1.5 V input with NPN or PNP interface reference
The initial state is off. T1 is the turn-on delay, T2 is the lighting interval and T3 is the turn-off delay. The stated limits are T1 ≤ 80 μs and T3 ≤ 80 μs.
5–24 V input with faster stated switching delay
The initial state is off. T1 is the turn-on delay, T2 is the lighting interval after trigger and T3 is the turn-off delay. The stated limits are T1 ≤ 5 μs and T3 ≤ 5 μs.
Match output voltage, load, channels, trigger and housing in one row
The family spans compact 24 V multi-channel controllers and 48 V single-channel high-power controllers. Do not transfer a trigger value or one-channel limit between rows.
- 1
Match the light voltage
Separate 24 V and 48 V loads before comparing power.
- 2
Calculate each output
Keep every light within the one-channel maximum.
- 3
Add the station load
Keep all active outputs within the total-power limit.
- 4
Confirm trigger and housing
Use the trigger voltage and dimension group from the same row.
LXV-2APC [voltage] [total output]-[channels]- LXV
- LuxMV product prefix
- 2APC
- Analogue controller family
- 24 / 48
- Output voltage
- 24–1500
- Total-output code
- 1 / 2 / 4 / 6 / 8
- Number of channels
| Class | Model | Output | Total power | One-channel maximum | Channels | Dimension | Trigger |
|---|---|---|---|---|---|---|---|
| Low power | LXV-2APC2424-1 | 24 V | 24 W | 24 W | 1 | 1 | 0–1.5 V |
| Low power | LXV-2APC2424-2 | 24 V | 24 W | 24 W | 2 | 1 | 0–1.5 V |
| Low power | LXV-2APC2424-4 | 24 V | 24 W | 24 W | 4 | 1 | 0–1.5 V |
| Medium power | LXV-2APC2460-1 | 24 V | 60 W | 60 W | 1 | 1 | 0–1.5 V |
| Medium power | LXV-2APC2460-2 | 24 V | 60 W | 30 W | 2 | 1 | 0–1.5 V |
| Medium power | LXV-2APC2460-4 | 24 V | 60 W | 24 W | 4 | 1 | 0–1.5 V |
| Medium power | LXV-2APC2460-6 | 24 V | 60 W | 24 W | 6 | 2 | 0–1.5 V |
| Medium power | LXV-2APC24120-1 | 24 V | 120 W | 120 W | 1 | 3 | 5–24 V |
| Medium power | LXV-2APC24120-2 | 24 V | 120 W | 60 W | 2 | 3 | 5–24 V |
| Medium power | LXV-2APC24120-8 | 24 V | 120 W | 24 W | 8 | 4 | 0–1.5 V |
| High power | LXV-2APC24200-1 | 24 V | 180 W | 180 W | 1 | 5 | 5–24 V |
| High power | LXV-2APC24400-1 | 24 V | 360 W | 360 W | 1 | 6 | 5–24 V |
| High power | LXV-2APC24400-2 | 24 V | 360 W | 180 W | 2 | 6 | 5–24 V |
| High power | LXV-2APC481000-1 | 48 V | 1000 W | 1000 W | 1 | 7 | 5–24 V |
| High power | LXV-2APC481500-1 | 48 V | 1500 W | 1500 W | 1 | 8 | 5–24 V |
Plan the exact enclosure, mounting method, ventilation and cable access
Eight mechanical groups cover DIN-rail, desktop, ventilated and handled housings. Use the dimension number in the model table to select the corresponding drawing.
| Group | Models | Width | Height | Depth | Housing |
|---|---|---|---|---|---|
| 1 | 2424-1/2/4; 2460-1/2/4 | 92 mm | 138 mm (145 overall) | 103 mm (111 overall) | DIN-rail base |
| 2 | 2460-6 | 130 mm | 153 mm (159.44 overall) | 102 mm (110 overall) | DIN-rail base |
| 3 | 24120-1/2 | 130 mm | 148 mm (155 overall) | 101 mm (109 overall) | DIN-rail base |
| 4 | 24120-8 | 138 mm | 78 mm (85 overall) | 219 mm (242 overall) | Desktop housing |
| 5 | 24200-1 | 130 mm | 148 mm (155 overall) | 101 mm (109 overall) | DIN-rail base |
| 6 | 24400-1/2 | 150 mm | 110 mm (116.5 overall) | 280 mm (327.61 overall) | Ventilated housing |
| 7 | 481000-1S | 154 mm | 110 mm (116.5 overall) | 355 mm (399 overall) | Ventilated housing |
| 8 | 481500-1S | 160 mm | 140 mm (148.6 overall) | 348 mm (430 overall) | Handled housing |
Use the drawing that matches the dimension number
Groups 1–3 and 5 identify removable DIN guide-rail bases and four M3 mounting holes. Larger housings use their shown feet, enclosure and ventilation arrangement.
Keep controls, connectors and airflow reachable